ST-LPW14-005
The 5 L/h version is the low-volume choice for occasional preparations that require this series UV and ultrafiltration configuration.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW14 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Main unit dimensions | H × W × D: 580 × 390 × 490 |
| Unit weight | 35 kg-45 kg |
| Power supply and rated power | 220 V/50 Hz 75 W (voltage tolerance±10%) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | ≤1-5 µS/cm (online monitoring), desalination rate 99% |
| Ultrapure water quality | resistivity 18.2 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | <0.1 CFU/mL |
| Particle count | < 1 particle/mL |
| Heavy-metal ions | <0.1 ppb |
| TOC | <5 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Endotoxin | <0.001 EU/mL |
| Evaporation residue | <1.0 mg/L |
| RNase | <0.5 |
| DNase | <5 |
| UF membrane cut-off | molecular-weight cut-off 5000 Da |
| UV oxidation and disinfection unit | 185/254 nm |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW14 Series combines UV treatment and ultrafiltration in the smaller 580 × 390 × 490 housing format. It supplies laboratory preparation where organic and biological contamination must be considered along with dissolved salts.
The 185/254 nm UV unit, 5,000 Da UF cut-off and low TOC requirement identify the treatment configuration. Production choices then determine how quickly water is replenished between collections; they should not be confused with changes in treatment quality.
MODELS AND DIMENSIONS
| Model | Production rate |
|---|---|
| ST-LPW14-005 | 5 L/h at 25°C |
| ST-LPW14-010 | 10 L/h at 25°C |
| ST-LPW14-020 | 20 L/h at 25°C |
| ST-LPW14-040 | 40 L/h at 25°C |
| ST-LPW14-060 | 60 L/h at 25°C |
| ST-LPW14-100 | 100 L/h at 25°C |
Production-rate ratings are stated at the temperature shown in the table.
MODEL DIFFERENCES
The 5 L/h version is the low-volume choice for occasional preparations that require this series UV and ultrafiltration configuration.
At 10 L/h, the system replenishes at twice the entry rating, useful when small preparations occur more often.
The 20 L/h option supplies a more regular preparation routine while retaining the same compact cabinet and treatment stages.
The 40 L/h model is the next production step for grouped preparation batches with less time between draws.
The 60 L/h configuration adds replenishment capacity for a longer sequence of analytical or reagent preparation tasks.
The 100 L/h option delivers the highest production rating in this format, for the largest recurring demand using the same UV/UF treatment.
FEATURES AND BENEFITS
The two stages address different contamination mechanisms within the specified water-treatment process.
The housing is substantially lower than the floor-standing versions, helping fit the treatment function into a bench-level service layout.
APPLICATIONS
Use for preparation methods whose full endotoxin and water-quality requirements match this configuration.
SYSTEM SELECTION
Use the supplied TOC, endotoxin and enzyme-related requirements to assess preparation needing more than an ionic-quality reading.
Choose the replenishment model for the workload and keep the compact UV-and-UF unit accessible for its treatment-stage maintenance.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.