Compact low-TOC configuration
The small housing combines local water collection with the stated organic requirement.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW13 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Production rate | 10/20/30/40/50/60/70/80/90/100/110/120 |
| Main unit dimensions | H × W × D: 650 × 530 × 420 |
| Unit weight | 35 kg-50 kg |
| Power supply and rated power | AC 220 V/50 Hz (power 70 W) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | conductivity ≤1-5 µS/cm (online monitoring) |
| Ultrapure water quality | resistivity 18.25 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | ≤0.1 CFU/mL |
| Particle count | ≤ 1 particle/mL |
| Heavy-metal ions | ≤0.1 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Evaporation residue | ≤1.0 mg/L |
| TOC | ≤3 ppb |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW13 Series supplies low-organic-background water from a compact system for laboratory preparation. Online resistivity monitoring provides an ionic-quality check, while the TOC specification addresses a different contaminant group.
Its listed production options and 650 × 530 × 420 housing format allow the unit to be considered within an existing bench layout. The practical choice is the required water quality and replenishment rate, rather than treating a small cabinet as evidence of low output.
MODELS AND DIMENSIONS
| Model |
|---|
| ST-LPW13-01 |
| ST-LPW13-02 |
| ST-LPW13-03 |
| ST-LPW13-04 |
| ST-LPW13-05 |
| ST-LPW13-06 |
Production-rate ratings are stated at the temperature shown in the table.
FEATURES AND BENEFITS
The small housing combines local water collection with the stated organic requirement.
The RO and ultrapure-water specifications allow tasks to be assigned according to the water each method actually requires.
APPLICATIONS
Match the organic and ionic limits to the method to reduce unwanted background introduced with preparation water.
SYSTEM SELECTION
Check the ionic and organic requirements of the intended preparation against the two outlet specifications, then identify which tasks need polished water.
Reserve the listed cabinet envelope plus connection access, and choose production for the laboratory’s batch pattern rather than cabinet size alone.