ST-LPW12-040
The 40 L/h option provides the entry output for low-TOC water preparation carried out in separated batches.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW12 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Production rate | 40/50/60/70/80/90/100/110/120 |
| Main unit dimensions | H × W × D: 650 × 530 × 420 |
| Unit weight | 35 kg-50 kg |
| Power supply and rated power | AC 220 V/50 Hz (power 70 W) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | conductivity ≤1-5 µS/cm (online monitoring) |
| Ultrapure water quality | resistivity 18.25 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | ≤0.1 CFU/mL |
| Particle count | ≤ 1 particle/mL |
| Heavy-metal ions | ≤0.1 ppb |
| absorbance (254 nm, 1 cmpath length) | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Evaporation residue | ≤1.0 mg/L |
| TOC | ≤3 ppb |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW12 Series prioritizes low organic background in laboratory water used for sensitive preparation. It combines high-resistivity water with a listed TOC limit so buyers can assess both ionic and organic contamination.
Unlike versions whose distinguishing requirement is endotoxin control, this configuration's useful published distinction is the 3 ppb TOC limit. Its 40–120 L/h model choices address replenishment duty within the common housing and dispensing arrangement.
MODELS AND DIMENSIONS
| Model | Production rate |
|---|---|
| ST-LPW12-040 | 40 L/h |
| ST-LPW12-050 | 50 L/h |
| ST-LPW12-060 | 60 L/h |
| ST-LPW12-070 | 70 L/h |
| ST-LPW12-080 | 80 L/h |
| ST-LPW12-090 | 90 L/h |
| ST-LPW12-100 | 100 L/h |
| ST-LPW12-110 | 110 L/h |
| ST-LPW12-120 | 120 L/h |
Select output capacity from daily consumption and peak dispensing demand.
MODEL DIFFERENCES
The 40 L/h option provides the entry output for low-TOC water preparation carried out in separated batches.
At 50 L/h, the model gives a small increase in replenishment for a schedule that is marginally too demanding for 40 L/h.
The 60 L/h version is a middle-low output choice for regular analytical preparation, with the same specified TOC limit as the larger versions.
The 70 L/h configuration fills the gap between 60 and 80 L/h when matching production to measured water consumption.
The 80 L/h model doubles the smallest rating, giving more recovery capacity for repeated reagent and sample-preparation batches.
The 90 L/h version adds output for longer preparation sessions without the full step to 100 L/h.
At 100 L/h, the selection emphasis is sustained consumption across consecutive batches rather than a different level of water purity.
The 110 L/h rating provides additional recovery between heavy draws where the 100 L/h model would have little spare production time.
The 120 L/h option offers the series maximum production for the busiest water-use schedule; it retains the common low-TOC specification.
FEATURES AND BENEFITS
A low TOC requirement helps select water for preparation where organic impurities can contribute to background signals.
The production-rate options support a measured increase in daily water use while preserving a common installation envelope.
APPLICATIONS
Match the organic and ionic limits to the method to reduce unwanted background introduced with preparation water.
SYSTEM SELECTION
Match the method’s TOC requirement to the listed low-organic specification before choosing among the production capacities.
Use the model output steps to cover recurring collections within the working day, with the compact housing and feed-water connections planned at the bench.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.