Two trace-contaminant requirements
Organic and endotoxin values allow the buyer to assess both influences rather than relying only on resistivity.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW11 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Production rate | 10/20/30/40/50/60/70/80/90/100/110/120 |
| Main unit dimensions | H × W × D: 650 × 530 × 420 |
| Unit weight | 35 kg-50 kg |
| Power supply and rated power | AC 220 V/50 Hz (power 70 W) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | conductivity ≤1-5 µS/cm (online monitoring) |
| Ultrapure water quality | resistivity 18.25 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | ≤0.1 CFU/mL |
| Particle count | ≤ 1 particle/mL |
| Heavy-metal ions | ≤0.1 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Endotoxin | ≤0.001 Eu/ml |
| Evaporation residue | ≤1.0 mg/L |
| TOC | ≤3 ppb |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW11 Series combines a low TOC limit with endotoxin control in a compact laboratory water system. It is intended for preparation work where both organic background and biological residues enter the water-quality decision.
The listed 3 ppb TOC limit distinguishes this option from versions focused on ionic purity alone. Its small housing supports bench-area installation, while the output configuration should be chosen around the sequence and size of water collections.
MODELS AND DIMENSIONS
| Model |
|---|
| ST-LPW11-01 |
| ST-LPW11-02 |
| ST-LPW11-03 |
| ST-LPW11-04 |
| ST-LPW11-05 |
| ST-LPW11-06 |
Production-rate ratings are stated at the temperature shown in the table.
FEATURES AND BENEFITS
Organic and endotoxin values allow the buyer to assess both influences rather than relying only on resistivity.
Producing and collecting water near the preparation area reduces the need to carry water between remote filling points and benches.
APPLICATIONS
Use for preparation methods whose full endotoxin and water-quality requirements match this configuration.
SYSTEM SELECTION
Select this configuration when the preparation method calls for the supplied combination of low organic background, endotoxin control and ionic purity.
Place the compact unit near the preparation area and choose production around the collection schedule while retaining access for consumable replacement.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.