Endotoxin-sensitive preparation
The endotoxin specification adds a biological-contaminant criterion beyond the ionic water-quality reading.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW07 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Production rate | 10/20/30/40/50/60/70/80/90/100/110/120 |
| Main unit dimensions | H × W × D: 650 × 530 × 420 |
| Unit weight | 35 kg-50 kg |
| Power supply and rated power | AC 220 V/50 Hz (power 70 W) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | conductivity ≤1-5 µS/cm (online monitoring) |
| Ultrapure water quality | resistivity 18.25 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | ≤0.1 CFU/mL |
| Particle count | ≤ 1 particle/mL |
| Heavy-metal ions | ≤0.1 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Endotoxin | ≤0.001 Eu/ml |
| Evaporation residue | ≤1.0 mg/L |
| TOC | ≤5 ppb |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW07 Series supplies laboratory water with separate controls for dissolved ions, organic background and endotoxin. It helps reagent-preparation work avoid treating a good resistivity reading as the complete description of water quality.
The compact configuration lists a TOC limit of 5 ppb together with an endotoxin limit. Those are meaningful selection details for methods sensitive to both contaminant groups; the hourly production options should then be matched to the laboratory's collection pattern.
MODELS AND DIMENSIONS
| Model |
|---|
| ST-LPW07-01 |
| ST-LPW07-02 |
| ST-LPW07-03 |
| ST-LPW07-04 |
| ST-LPW07-05 |
| ST-LPW07-06 |
Production-rate ratings are stated at the temperature shown in the table.
FEATURES AND BENEFITS
The endotoxin specification adds a biological-contaminant criterion beyond the ionic water-quality reading.
The listed compact dimensions help reserve space for the main unit without assuming its service connections or consumable-access clearance.
APPLICATIONS
Use for preparation methods whose full endotoxin and water-quality requirements match this configuration.
SYSTEM SELECTION
Assess organic background and endotoxin together for the intended reagent procedure rather than selecting from the resistivity reading alone.
Match the production configuration to repeated batch demand and reserve space for feed, drain and service connections around the listed housing.