Cleanroom Pure Water Systems

Laboratory Ultrapure Water System – ST-LPW06 Series

Product specifications

BrandST
Public model seriesST-LPW06
Feed-water sourceDistilled water, purified water or Type II purified water
Feed-water SDI<1
Feed-water temperature5–45°C
Feed-water TDS<50 ppm
Feed-water pressure1.5–4 bar
Maximum feed conductivity<50 µS/cm
Power supply220 V / 50 Hz
Rated power35 W
Ultrapure-water resistivity18.25 MΩ·cm

Customization availableSpecifications can be customized to your requirements.

Request a quotation

Specify the quantity and configuration in your inquiry.

Laboratory Ultrapure Water System – ST-LPW06 Series polishes already purified feed water at a laboratory use point. It is suited to a bench supplied by distilled water, purified water or Type II water, where the final treatment is located close to the work.

The low feed-water TDS, conductivity and SDI requirements distinguish this unit from a system intended to treat incoming municipal water directly. Its 35 W rating supports a local polishing arrangement, while the upstream supply must maintain the stated feed conditions.

FEATURES AND BENEFITS

How it helps

Use an existing purified feed

Local polishing can be added at the laboratory point without describing the unit as a raw-water treatment plant.

Feed quality matters

The feed conductivity and SDI limits address the load entering the polishing stage and protect the intended operating arrangement.

APPLICATIONS

Where it is used

01

Laboratory point-of-use polishing

Treat an existing purified-water feed close to reagent preparation instead of treating municipal water directly at the bench.

SELECTION GUIDANCE

Choosing the configuration

Existing purified-water connection

Connect to a distilled, purified or Type II water line that maintains the stated pressure and temperature at the unit during collection. Allow access to the feed tubing and service connections beside the bench.

Feed quality and preparation method

Match the upstream water to the TDS, conductivity and SDI limits together, then use the listed outlet resistivity to assess the preparation method. Select the polishing unit around the existing purified supply.

PROCUREMENT / INQUIRY

Request a
product quotation.

Tell us the quantity and configuration you need. This product will be included automatically.

Fields marked * are required.

YOUR PRODUCTLaboratory Ultrapure Water System – ST-LPW06 SeriesReview specifications
Useful details for this quotation

Include the analytical task and demand pattern so treatment and dispensing match the laboratory.

  • Application and water-quality requirement
  • Daily and peak water demand
  • Feed-water analysis
  • Dispensing and installation space

We use your contact details and requirements to review your inquiry and prepare a quotation. Sending this form does not place an order.

Laboratory Ultrapure Water System – ST-LPW06 Series — product view

YOUR PURCHASING BRIEF

Inquiry list

Collect products here, then send your requirements in one inquiry.

Continue to inquiry ↗

This list is saved in this browser. Adding a product does not place an order.