ST-LPW05-005
At 5 L/h, this is the smallest replenishment option for occasional small reagent preparations with long intervals between draws.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW05 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Main unit dimensions | H × W × D: 650 × 530 × 420 |
| Unit weight | 35 kg-50 kg |
| Power supply and rated power | AC 220 V/50 Hz (power 50 W) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | conductivity ≤1-5 µS/cm (online monitoring) |
| Ultrapure water quality | resistivity 18.25 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | ≤0.1 CFU/mL |
| Particle count | ≤ 1 particle/mL |
| Heavy-metal ions | ≤0.1 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Evaporation residue | ≤1.0 mg/L |
| TOC | ≤5 ppb |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW05 Series provides a smaller laboratory water-production format for work involving both routine rinsing and low-background reagent preparation. Online water-quality readings help staff decide whether the outlet is ready for their method.
This configuration combines a compact housing with output choices from intermittent bench use to heavier daily demand. The TOC limit is a separate selection criterion from resistivity, because dissolved organic background can affect an analytical method even when ionic purity is high.
MODELS AND DIMENSIONS
| Model | Production rate |
|---|---|
| ST-LPW05-005 | 5 L/h at 25°C |
| ST-LPW05-010 | 10 L/h at 25°C |
| ST-LPW05-020 | 20 L/h at 25°C |
| ST-LPW05-040 | 40 L/h at 25°C |
| ST-LPW05-060 | 60 L/h at 25°C |
| ST-LPW05-100 | 100 L/h at 25°C |
Production-rate ratings are stated at the temperature shown in the table.
MODEL DIFFERENCES
At 5 L/h, this is the smallest replenishment option for occasional small reagent preparations with long intervals between draws.
The 10 L/h model doubles the entry production rate, giving a small-volume workstation more recovery capacity during the day.
The 20 L/h version supports a more regular preparation schedule, with twice the production of the 10 L/h option.
A 40 L/h rating provides the next step when several preparation batches leave the lower-output models too little time to replenish.
The 60 L/h model adds sustained production for repeated analytical preparation while retaining the same listed low-TOC water specification.
The 100 L/h version is the capacity choice for the greatest cumulative water use; select it for replenishment demand rather than a different dispensing speed.
FEATURES AND BENEFITS
Lower-output versions suit spaced collections; higher-output versions replenish water more quickly between preparation batches.
The specified TOC and resistivity address different types of contamination and should both be matched to the method.
APPLICATIONS
Match the organic and ionic limits to the method to reduce unwanted background introduced with preparation water.
SYSTEM SELECTION
Compare the method’s organic-background requirement with this unit’s TOC specification as well as its ionic-water quality.
Choose a production model for the interval between preparation batches, allowing service access around the compact cabinet at the bench.