ST-LPW39-060
The 60 L/h entry version suits a measured biochemistry water-use schedule with recovery time between preparation and cleaning periods.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW39 |
| Feed water | Municipal water; TDS ≤200 ppm; 1.0–5.0 kg/cm²; 5–45°C |
| Production rate | 60/80/100/120/150 L/h |
| Dimensions | 1430 × 525 × 570 mm |
| Weight | 30–50 kg |
| Power | AC 220 V, 50 Hz; 50 W |
| Dispensing rate | 1.8–2.0 L/min |
| RO-water conductivity | ≤0.1 µS/cm, online monitoring |
| Microbial level | ≤1 CFU/mL |
| Particle level | ≤1 particle/mL |
| Endotoxin | ≤0.001 EU/mL |
| Absorbance | ≤0.01 at 254 nm, 1 cm path |
| Soluble silica | ≤0.01 mg/L |
| Evaporation residue | <1.0 mg/L |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Biochemistry Laboratory Pure Water System – ST-LPW39 Series turns municipal water into monitored low-conductivity RO water for biochemical laboratories. It supports analyser feed, glassware and ultrasonic washing, reagent preparation and compatible sterilizer or humidifier use.
Production models from 60 to 150 L/h share automatic pretreatment, online monitoring and low-water protection.
MODELS AND DIMENSIONS
| Model | Production rate |
|---|---|
| ST-LPW39-060 | 60 L/h |
| ST-LPW39-080 | 80 L/h |
| ST-LPW39-100 | 100 L/h |
| ST-LPW39-120 | 120 L/h |
| ST-LPW39-150 | 150 L/h |
MODEL DIFFERENCES
The 60 L/h entry version suits a measured biochemistry water-use schedule with recovery time between preparation and cleaning periods.
The 80 L/h model adds production for repeated preparation or instrument-water draws within the same working session.
The 100 L/h configuration is the middle output choice for sustained laboratory demand across consecutive batches.
The 120 L/h option provides more recovery margin when analysis and cleaning use water during closely spaced periods.
At 150 L/h, this is the largest production version for high cumulative demand; it is selected by consumption rather than a change in water-quality specification.
PROCESS AND CONTROL
One system can feed compatible analysers and routine washing points at the stated water quality.
Conductivity monitoring gives the operator an immediate check before use.
The unit stops on low feed pressure and resumes production after normal supply returns.
APPLICATION ENVIRONMENTS
Supplies analysers, reagent preparation and calibration-material reconstitution.
Provides a consistent alternative to manually prepared distilled water for routine work.
Supports compatible ultrasonic washers, humidifiers and high-pressure sterilizers.
SYSTEM SELECTION
Identify which analyser, washing or utility tasks will use the RO supply and compare each device’s water-quality and connection requirements.
Select production from their combined peak consumption, allowing accessible feed, drain and consumable-service connections at the floor-standing unit.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.