Biopharmaceutical production
Pass prepared materials and tools into clean production rooms through a dedicated chamber.
Modular Cleanroom Systems
| Brand | ST |
|---|---|
| Product type | Laminar flow pass box |
| Chamber sizes | 400 / 500 / 600 / 800 |
| Cabinet material | Stainless steel; grade specified with the order |
| Door interlocking | Electronic interlock |
| Doors | Double-layer tempered glass doors |
| Handles | Stainless steel crescent handles |
| Fan | Centrifugal fan |
| Filter | Gel-seal high-efficiency filter |
| Return air | Perforated return-air grille |
| Pressure indication | Differential-pressure gauge |
| Control panel | Centralized controls |
| Filter test connections | PAO injection port and PAO test port |
| UV treatment | UV disinfection lamp |
| Air velocity | 0.45 m/s ± 20% |
| Power range | 0.2–0.5 kW (200–500 W), depending on size |
| Noise | 65 dB |
| Adjustable cycle timer | 0–999 min |
| Chamber cleanliness | Grade A |
| Electrical supply | Voltage, phase and frequency specified with the order |
| Customization | Appearance, functions and dimensions |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laminar Flow Pass Box moves small items between cleanrooms or from an adjoining non-clean area into a clean area, reducing personnel-door openings. Laminar filtered airflow cleans the chamber air, while electronic interlocking separates access from each side.
A gel-seal high-efficiency filter and return-air grille support chamber circulation. UV treatment supports the transfer hygiene procedure, and PAO ports provide access for filter integrity checks.
MODELS AND DIMENSIONS
| Size | External dimensions (mm) | Work chamber (mm) | Filter dimensions (mm) | Power (kW / W) | Air velocity (m/s) | Noise (dB) | Adjustable cycle (min) | Chamber cleanliness |
|---|---|---|---|---|---|---|---|---|
| 400 | 615 × 470 × 1000 | 400 × 400 × 400 | 230 × 180 × 90 | 0.2 kW / 200 W | 0.45 m/s ± 20% | 65 dB | 0–999 min | Grade A |
| 500 | 715 × 570 × 1100 | 500 × 500 × 500 | 330 × 280 × 90 | 0.3 kW / 300 W | 0.45 m/s ± 20% | 65 dB | 0–999 min | Grade A |
| 600 | 815 × 670 × 1200 | 600 × 600 × 600 | 430 × 380 × 90 | 0.4 kW / 400 W | 0.45 m/s ± 20% | 65 dB | 0–999 min | Grade A |
| 800 | 1015 × 870 × 1400 | 800 × 800 × 800 | 630 × 580 × 90 | 0.5 kW / 500 W | 0.45 m/s ± 20% | 65 dB | 0–999 min | Grade A |
Grade A applies to the chamber, with test conditions and acceptance requirements agreed for the selected configuration.
APPLICATION ENVIRONMENTS
Pass prepared materials and tools into clean production rooms through a dedicated chamber.
Transfer small components into clean assembly areas while limiting personnel-door openings.
Move cleaned parts and instruments into particle-controlled assembly rooms.
Transfer compatible supplies between preparation rooms and adjacent clean areas.
Pass packaged ingredients, utensils and materials into designated clean production areas.
MAIN FEATURES
The centrifugal fan, gel-seal filter and return grille reduce airborne particles during the transfer cycle.
Electronic interlocking prevents simultaneous door opening, limiting direct air exchange between rooms.
PAO injection and test ports support integrity checks; the pressure gauge shows the monitored pressure difference.
Glass doors allow inspection, while stainless steel surfaces support routine cleaning and UV treatment.
SELECTION GUIDE
Choose a chamber with handling clearance, then match the cabinet to the wall opening.
Specify the electrical supply, transfer cycle and required appearance or functional changes.
COMMON QUESTIONS
They provide access for aerosol-based filter integrity testing during commissioning and maintenance.
No. Items still follow the required cleaning procedure; UV treatment depends on exposure and the load.
No. Interlocked access limits direct air exchange; room pressure also depends on the ventilation system.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.