ST / INTEGRATED CLEANROOM PROCUREMENTEquipment / Consumables / Supporting facilities
PRODUCT / TECHNICAL DATA Modular Cleanroom SystemsSpecifications / Configurations / Procurement

Modular Cleanroom Systems

Cleanroom Pass Box

Product specifications

Product configurationPass box with recirculating filtered airflow
Door interlockingElectromagnetic interlock; operating sequence configured for the application
Work chamberRounded internal transitions for access during cleaning
Reference outlet air velocity0.45 m/s ± 20%; final operating duty confirmed for the selected system
Reference noise65 dB; measurement conditions to be agreed where required
Reference equipment power0.2 kW (200 W) for the first five configurations; 0.3 kW (300 W) for the 800 mm and 1000 mm configurations
Power supplyVoltage, phase and frequency specified for the destination installation; confirm before ordering
Door optionsTempered-glass doors with stainless steel frames; inset or suspended glass arrangements available
Controls and wiringEnglish-language interface available; manual or automatic operation; top or side cable entry
Additional configurationsCorner transfer, three-door and two-tier layouts can be specified
Optional UV lamp configurationTwo lamps per reference configuration; 6 W, 8 W, 15 W or 20 W per lamp, depending on chamber size

Customization availableSpecifications can be customized to your requirements.

Request a quotation

Specify the quantity and configuration in your inquiry.

Cleanroom Pass Box provides a dedicated handover point for small materials between rooms. Electromagnetic interlocking controls the two doors, while filtered circulation cleans the chamber air.

Glazed doors show the contents, and rounded internal transitions make routine cleaning easier.

MODELS AND DIMENSIONS

Compare dimensions and technical specifications

Each value includes its unit. UV lamp ratings are optional configurations. Confirm dimension orientation on the approved installation drawing.
Size configurationWork chamber (mm)External dimensions (mm)Equipment power (kW / W)Outlet air velocity (m/s)Noise (dB)Optional UV lamps (W)
400 mm chamber400 × 400 × 400 mm620 × 460 × 950 mm0.2 kW (200 W)0.45 m/s ± 20%65 dB2 × 6 W (12 W total)
500 mm chamber500 × 500 × 500 mm720 × 560 × 1050 mm0.2 kW (200 W)0.45 m/s ± 20%65 dB2 × 8 W (16 W total)
600 mm chamber600 × 600 × 600 mm820 × 660 × 1150 mm0.2 kW (200 W)0.45 m/s ± 20%65 dB2 × 8 W (16 W total)
600 × 600 × 800 mm chamber600 × 600 × 800 mm820 × 660 × 1350 mm0.2 kW (200 W)0.45 m/s ± 20%65 dB2 × 8 W (16 W total)
700 mm chamber700 × 700 × 700 mm920 × 760 × 1250 mm0.2 kW (200 W)0.45 m/s ± 20%65 dB2 × 15 W (30 W total)
800 mm chamber800 × 800 × 800 mm1020 × 860 × 1350 mm0.3 kW (300 W)0.45 m/s ± 20%65 dB2 × 20 W (40 W total)
1000 mm chamber1000 × 1000 × 1000 mm1220 × 1060 × 1600 mm0.3 kW (300 W)0.45 m/s ± 20%65 dB2 × 20 W (40 W total)

All specifications can be customized. Equipment power and optional UV lamp ratings are listed separately; confirm the total connected load, supply voltage, phase and frequency for the ordered configuration. Include door movement, wall interfaces and maintenance access in the installation drawing.

APPLICATION ENVIRONMENTS

Applications

01

Production rooms receiving components and tools

Pass prepared components and tools into production rooms through a dedicated chamber.

02

Cleanroom preparation and support areas

Move supplies between cleanroom preparation and support areas with controlled door access.

03

Laboratory support rooms handling non-hazardous supplies

Transfer non-hazardous supplies between laboratory support rooms.

PRACTICAL BENEFITS

Key features

Separate loading from collection

Interlocked doors separate loading from collection on the opposite side.

Check contents through the closed door

Glazing helps operators check the load; rounded internal transitions simplify wiping.

Bring filtered circulation into the chamber

Filtered circulation reduces airborne particles within the chamber during operation.

CHOOSING THE ASSEMBLY

Selection

Container and hand clearance

Allow chamber space for the largest container and comfortable handling.

Wall and transfer direction

Match cabinet dimensions and door direction to the wall and transfer route.

PRODUCT QUESTIONS

Common questions

Can the pass box replace a personnel air shower?

No. A pass box transfers materials; a personnel air shower is designed for people.

Does the optional UV lamp make every transferred item sterile?

No. UV performance depends on exposure and the load; a lamp alone does not establish a sterile transfer process.

PROCUREMENT / INQUIRY

Request a
product quotation.

Tell us the quantity and configuration you need. This product will be included automatically.

Fields marked * are required.

YOUR PRODUCTCleanroom Pass BoxReview specifications
Useful details for this quotation

Choose the clear chamber around the loaded container, leaving enough room to place and retrieve it.

  • Largest transfer load
  • Wall opening and thickness
  • Door access arrangement
  • Interlock preference

We use your contact details and requirements to review your inquiry and prepare a quotation. Sending this form does not place an order.

Cleanroom Pass Box — product view

YOUR PURCHASING BRIEF

Inquiry list

Collect products here, then send your requirements in one inquiry.

Continue to inquiry ↗

This list is saved in this browser. Adding a product does not place an order.