ST / INTEGRATED CLEANROOM PROCUREMENTEquipment / Consumables / Supporting facilities
PRODUCT / TECHNICAL DATA Cleanroom Disinfection SuppliesSpecifications / Configurations / Procurement

Cleanroom Disinfection Supplies

Mobile Ozone Generator

Product specifications

BrandST
Product typeMobile ozone generator
Rated voltage220 V
Cabinet material304 stainless steel
ControlDigital programmable time switch
MobilityFloor-standing cabinet with castors
Main functionsGermicidal treatment, disinfection and odour removal
Treatment targetsBacteria, viruses and fungal spores
Disinfection rate99.99%
Gas distribution360-degree diffusion through the treatment space
Treatment mediumOzone gas; no added liquid disinfectant
Ozone decompositionBreaks down into oxygen after generation stops
Cabinet propertiesCorrosion, rust, acid and alkali resistance
Reference configuration output20–40 g/h
CustomisationOzone output and project-specific configuration

Customization availableSpecifications can be customized to your requirements.

Request a quotation

Specify the quantity and configuration in your inquiry.

Mobile Ozone Generator produces ozone for scheduled room disinfection and odour treatment. Ozone is a reactive gas that oxidises susceptible microorganisms and odour-causing compounds as it spreads through the treatment area. It is used in an isolated, unoccupied space after routine cleaning.

Castors let the unit move between treatment areas, while the digital time switch schedules operating periods. The 304 stainless steel cabinet resists corrosion and is easy to clean, making the unit practical for shared use across rooms without a permanent installation in each one.

MODELS AND DIMENSIONS

Ozone output options

Choose the output configuration for the treatment volume and operating cycle.
Ozone output (g/h)CabinetControl
10304 stainless steelDigital time switch
20304 stainless steelDigital time switch
30304 stainless steelDigital time switch
40304 stainless steelDigital time switch
50304 stainless steelDigital time switch
60304 stainless steelDigital time switch
80304 stainless steelDigital time switch
100304 stainless steelDigital time switch
120304 stainless steelDigital time switch
150304 stainless steelDigital time switch
180304 stainless steelDigital time switch
200304 stainless steelDigital time switch

Output is the mass of ozone generated per hour. Room concentration also depends on room volume, air movement and ozone consumption by surfaces.

MOBILE GAS TREATMENT

Timed treatment without liquid spraying

Gas-phase contact

Ozone moves with the room air to contact exposed areas; effective treatment depends on gas distribution, concentration and contact time.

Scheduled operation

The time switch sets operating periods around room availability, avoiding continuous generation when treatment is not required.

One unit, multiple rooms

The wheeled cabinet can be repositioned between treatment cycles, reducing the need for a fixed generator in every room.

No liquid disinfectant dosing

Ozone is generated on site and subsequently decomposes, avoiding preparation and spraying of a liquid disinfectant for this treatment step.

APPLICATION ENVIRONMENTS

Rooms that can be isolated for treatment

01

Industrial workrooms

Schedule room disinfection after cleaning and outside working hours, with a treatment cycle established for the target microorganisms.

02

Storage and utility rooms

Treat suitable empty rooms for residual odours after the source has been removed, with ozone-compatible fittings and materials.

03

Vacated commercial premises

Use controlled odour-treatment cycles during building cleaning or restoration before occupants return.

OPERATING CONDITIONS

Control exposure throughout the treatment cycle

Isolate the area

Keep people, animals and plants out during operation and prevent ozone from reaching occupied adjacent spaces; inhaling ozone can injure the lungs.

Release the room after measurement

After switching off, ventilate or use the site's ozone-removal procedure and measure residual ozone before re-entry. The timer ending or the smell disappearing does not establish safe entry.

CONFIGURATION AND USE

Size the treatment for the room and its contents

Output and contact time

Select output using room volume, air movement and target concentration, then establish contact time for the organisms or odours being treated.

Materials and cleaning

Remove the contamination source and clean first; assess rubber seals, cable coatings, fabrics and other ozone-sensitive contents before treatment.

PROCUREMENT / INQUIRY

Request a
product quotation.

Tell us the quantity and configuration you need. This product will be included automatically.

Fields marked * are required.

YOUR PRODUCTMobile Ozone GeneratorReview specifications
Useful details for this quotation

Describe the treatment task and how operation is separated from normal room use so the configuration can be reviewed.

  • Treatment task and space
  • Required operating arrangement
  • Mounting or integration space
  • Site power supply

We use your contact details and requirements to review your inquiry and prepare a quotation. Sending this form does not place an order.

Mobile Ozone Generator — product view

YOUR PURCHASING BRIEF

Inquiry list

Collect products here, then send your requirements in one inquiry.

Continue to inquiry ↗

This list is saved in this browser. Adding a product does not place an order.