1000 mm deep configuration
The compact coated-steel chamber supports single-person passage where entrance depth is limited; it uses the listed 0.7 kW supply load.
Cleanroom Equipment
| Specification | Single-person | Two-person | Multi-person |
|---|---|---|---|
| Brand | ST | ||
| Material | Spray-coated steel | ||
| Model | ST-PT2 | ||
| External size (W × D × H, mm) | 1400 × 1000 × 2100 | 1400 × 1500 × 2100 | 1400 × 2000 × 2100 |
| Internal size (W × D × H, mm) | 800 × 1000 × 1960 | 800 × 1500 × 1960 | 800 × 2000 × 1960 |
| Filtration efficiency | 99.995% at 0.5 µm | ||
| Air velocity | 26 m/s ±10% | ||
| Standard functions | Electronic interlock; voice prompts; sensor-activated LED lighting | ||
| Power | 0.7 kW | 1.15 kW | 1.4 kW |
| Power supply | 380 V / 50 Hz or 220 V / 50 Hz | ||
| Weight | 160 kg/m | ||
| Size customization | Custom dimensions available | ||
Customization availableChamber dimensions can be customized to fit the personnel entrance and planned group size.
Specify the quantity and configuration in your inquiry.
Air Shower-1 removes loose dust from clothing before staff enter clean production, helping keep particles from settling on exposed products during assembly or packing. Filtered jets loosen the dust inside the chamber, while return air carries the dislodged particles back through filtration for collection.
The spray-coated steel enclosure provides a finished surface for routine wiping at an indoor entrance. Electronic interlocking prevents both doors from opening together, and voice prompts guide staff through the entry procedure. Sensor-activated LED lighting makes the chamber visible during use; three chamber lengths accommodate individual entry or small groups.
MODEL DIFFERENCES
The compact coated-steel chamber supports single-person passage where entrance depth is limited; it uses the listed 0.7 kW supply load.
The two-person layout adds 500 mm of passage length without changing the listed width or height, with 1.15 kW power.
The longest chamber supports the multi-person entry arrangement at 1.4 kW; the extra depth needs corresponding room for the approach and exit.
PRACTICAL BENEFITS
Return air carries loose particles away from the clothing and back to the filter, adding particle collection to the garment dust-removal step.
Interlocked doors keep the two sides from being open together while staff pass between the changing area and production.
The finished steel panels can be wiped during routine entrance cleaning; non-abrasive cleaning helps protect the coating.
APPLICATION ENVIRONMENTS
Use at the personnel entrance to reduce clothing dust carried toward uncovered parts and assembly surfaces.
Add the chamber to the gowning route where loose particles can settle on components awaiting finishing or inspection.
Place before the packing area to remove loose clothing dust before workers handle open products and packaging.
SELECTION GUIDE
Select a chamber length that gives the planned users room to stand during blowing, and allow waiting space outside the entrance.
Use cleaning materials compatible with the finish and avoid abrasive scrubbing that can damage the coated surface.
Allow door clearance and filter-maintenance access, and match the electrical supply to the installation.
COMMON QUESTIONS
Include the air shower in the site gowning procedure, close the entry door and follow the voice prompts before proceeding into production.
Use a non-abrasive wipe and a cleaning agent compatible with the coating, then remove residue as part of the room cleaning routine.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.